Products

Products

36 kV High Voltage Vacuum Circuit Breaker
  • 36 kV High Voltage Vacuum Circuit Breaker36 kV High Voltage Vacuum Circuit Breaker
  • 36 kV High Voltage Vacuum Circuit Breaker36 kV High Voltage Vacuum Circuit Breaker
  • 36 kV High Voltage Vacuum Circuit Breaker36 kV High Voltage Vacuum Circuit Breaker

36 kV High Voltage Vacuum Circuit Breaker

The 36 kV High Voltage Vacuum Circuit Breaker is a three-phase indoor switching device designed for 36kV distribution and sub-transmission systems. It combines vacuum interrupter technology with a spring stored-energy operating mechanism, providing reliable control and protection for feeders, transformers, capacitor banks, and bus-tie circuits in substations, industrial plants, and renewable energy installations.

    Fixed and Withdrawable Configurations

    The 36 kV High Voltage Vacuum Circuit Breaker is available in two installation formats. As a fixed-mounted unit, the breaker is bolted directly into switchgear panels for applications where maintenance frequency is low and panel downtime can be scheduled. As a withdrawable handcart unit, it can be isolated and removed from a live panel in minutes, making it the preferred choice for critical infrastructure where maintenance downtime must be minimized. For 36kV systems, the withdrawable format is standard in metal-clad switchgear serving transmission substations and heavy industrial loads.

    75 kV High Voltage Vacuum Circuit Breaker75 kV High Voltage Vacuum Circuit Breaker

    Product model and the meaning

    75 kV High Voltage Vacuum Circuit Breaker

    Design Features

    The 36 kV High Voltage Vacuum Circuit Breaker is built around design choices that matter at 36kV:

    Vacuum interruption without SF₆ — eliminates greenhouse gas risk and the need for gas monitoring, leak detection, and periodic gas replenishment associated with SF₆ switchgear.

    Embedded pole or column-type interrupter design — protects the vacuum interrupter from mechanical damage and environmental contamination, supporting stable dielectric performance over the service life.

    Spring stored-energy mechanism — provides reliable closing and opening energy independent of the operator, with manual charging for commissioning and electric charging for normal operation.

    Low maintenance requirement — vacuum interruption removes arc-quenching media degradation as a maintenance driver, reducing routine intervention compared with older technologies.

    Cabinet Width Rated Current Main Dimension Characteristics
    800mm 630A-1600A Compact structure for medium current applications
    1000mm 630A-1600A Suitable for larger cabinet configurations
    1000mm 1600A-5000A Designed for higher current requirements

    The optimized mechanical layout helps reduce installation difficulties while improving equipment coordination with high-voltage switchgear.

    VS1 Structure Drawing & Installation Dimensions

    75 kV High Voltage Vacuum Circuit Breaker

    Fixed Type VS1 Structure Drawing & Installation Dimensions

    75 kV High Voltage Vacuum Circuit Breaker

    Applications

    The 36 kV High Voltage Vacuum Circuit Breaker is specified across several application categories where 36kV switching and protection are required:

    Transmission and distribution substations — as main breaker, bus-tie breaker, and feeder protection in 36kV indoor switchgear.

    Renewable energy integration — protection of wind turbine step-up transformers and solar farm collector circuits at 36kV, where frequent switching and high mechanical endurance are required.

    Heavy industry — switching and fault interruption for large motors, arc furnaces, and industrial distribution feeders in mining, steel, and chemical facilities.

    Railways and infrastructure — 36kV switching in traction power substations and critical infrastructure distribution.

    Electrical Control System

    Reliable Control Circuit Design

    The control system directly affects the operating reliability of high-voltage switching equipment.

    The Usune 36 kV High Voltage Vacuum Circuit Breaker adopts a professional control circuit design with optional components including closing coil, opening coil, auxiliary switches, blocking coil, motor energy storage system, and over-current tripping coil.

    Component Function
    HQ Closing Coil Controls breaker closing operation
    TQ Opening Coil Controls breaker opening operation
    M Motor Provides energy storage function
    S1 Auxiliary Switch Indicates energy storage status
    S8 Auxiliary Switch Indicates test position
    S9 Auxiliary Switch Indicates working position
    Y1 Blocking Coil Provides operation locking protection
    Y7-Y9 Over Current Coil Provides over-current protection

    This configuration allows engineers to customize the control system according to different project requirements.

    Protection Functions

    Protection functions are critical to safe and reliable switching in a 36 kV High Voltage Vacuum Circuit Breaker. The optional functions below help prevent abnormal switching actions, block unsafe closing operations, and provide fault tripping when current exceeds preset limits.

    Anti-Bounce Control

    During electrical operation, repeated closing signals may cause abnormal switching actions. The optional anti-bounce relay helps prevent repeated closing operations by disconnecting the closing circuit when the closing signal remains active for too long. This function improves operating stability and protects the mechanical operating mechanism from unnecessary repeated actions.

    Blocking Protection

    The blocking function prevents incorrect operation when control conditions are not satisfied. When the secondary control power supply is not activated or does not meet the required voltage range, the blocking mechanism prevents unsafe closing operations. This design improves operational safety in complex high-voltage environments.

    Over-Current Protection

    The optional over-current tripping function provides intelligent fault protection. The system receives three-phase current signals from the current transformer secondary side and compares them with preset values. When the current exceeds the setting value, the protection unit sends a trip signal to open the circuit breaker and complete the fault protection process.

    Protection Function Description
    Current Detection Monitors A, B, C phase current signals
    Signal Comparison Compares current values with preset settings
    Trip Output Activates breaker opening operation
    Protection Result Disconnects fault current safely

    Wiring Configuration

    Flexible Connection Options

    Different projects may require different control circuit arrangements.

    The product supports optional wiring configurations based on customer requirements, including combinations with anti-bounce function, blocking function, and operating power options.

    Configuration Anti-Bounce Blocking Function
    Standard Control Optional Optional
    Protection Configuration Available Available
    Customized Wiring According to project requirement According to project requirement

    The flexible wiring design allows better integration with different protection and automation systems.

    DC Power Connection Notice

    When using DC power operation, the polarity of the dashed box terminals should remain consistent.

    The motor wiring polarity should follow the specified circuit diagram to ensure correct energy storage operation.

    The wiring diagram represents the breaker under test position condition without energy storage and in the open state.

    Correct wiring is essential for reliable operation of the control system.

    Why Choose This 36 kV High Voltage Vacuum Circuit Breaker for Your Project

     For panel builders, EPCs, and system integrators working on 36kV projects, this 36 kV High Voltage Vacuum Circuit Breaker offers a combination that reduces integration friction: IEC 62271-100-aligned ratings, fixed and withdrawable formats from a single product family, and compatibility with metal-clad switchgear used in substation and renewable energy applications. USUNE supplies each unit with model-specific datasheets, outline drawings, wiring diagrams, and factory routine test records, so the breaker can move from specification to panel integration and commissioning with documentation matched to the delivered configuration.

    Product Comparison

    Standard Configuration vs Protection Configuration

    When selecting high-voltage circuit breakers, customers often need to balance operational requirements and protection functions.

    Comparison Item Standard Configuration Protection Configuration
    Basic Switching Function Available Available
    Anti-Bounce Function Optional Included when required
    Blocking Protection Optional Available
    Over-Current Protection External requirement Integrated option
    System Safety Level Standard operation Enhanced protection

    Different Current Capacity Options

    Different power systems require different current capabilities.

    Rated Current Range Recommended Application
    630A-1600A Medium load distribution systems
    1600A-5000A Higher capacity power systems

    Selecting the correct current rating helps improve system efficiency and prevent equipment overload.

    Technical Specifications

    Parameter Specification
    Product Type 36 kV High Voltage Vacuum Circuit Breaker
    Series VS1
    Installation Type Fixed Type
    Rated Current 630A-5000A
    Cabinet Width 800mm / 1000mm
    Interruption Technology Vacuum Arc Interruption
    Control Options Anti-Bounce / Blocking / Over-Current Protection
    Standards IEC and GB
    Certification CE

    Ordering Information

    Required Technical Details

    To ensure correct configuration, customers should provide complete technical requirements before ordering.

    Information Purpose
    Rated voltage Confirm system voltage level
    Rated current Select suitable capacity
    Cabinet dimensions Ensure installation compatibility
    Control voltage Match operating system
    Wiring requirements Confirm optional functions
    Protection requirements Select additional modules

    Accurate technical information helps shorten engineering confirmation time and improves project efficiency.

    Quality Certification

    International Manufacturing Standards

    Usune applies strict quality management throughout product development, manufacturing, and testing.

    Certification Standard
    Quality Management ISO 9001
    Environmental Management ISO 14001
    Occupational Safety Management ISO 45001
    Electrical Standard IEC and GB
    Product Certification CE

    These certifications demonstrate Usune's commitment to supplying reliable high-voltage electrical equipment for global customers.

    FAQ

    What factors should be considered when selecting a 36 kV High Voltage Vacuum Circuit Breaker?

    Customers should consider rated voltage, rated current, cabinet compatibility, control requirements, and protection functions.

    Can the breaker support customized control functions?

    Yes. Functions such as anti-bounce control, blocking protection, and over-current tripping can be configured according to project requirements.

    Why is cabinet dimension compatibility important?

    Correct mechanical matching reduces installation modifications and improves system integration efficiency.

    What protection functions are available?

    The product can support anti-bounce control, blocking protection, and intelligent over-current tripping functions.

    Send Inquiry
    Contact Info
    If you have any inquiry about a quotation or cooperation, please feel free to email or use the following inquiry form. Our sales representative will contact you within 24 hours.
    X
    We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
    RejectAccept