2000kVA Three-Phase Dry Type Transformer
  • 2000kVA Three-Phase Dry Type Transformer2000kVA Three-Phase Dry Type Transformer
  • 2000kVA Three-Phase Dry Type Transformer2000kVA Three-Phase Dry Type Transformer
  • 2000kVA Three-Phase Dry Type Transformer2000kVA Three-Phase Dry Type Transformer

2000kVA Three-Phase Dry Type Transformer

The Usune 2000kVA Three-Phase Dry Type Transformer is an oil-free power distribution unit that utilizes air as both the cooling and insulating medium. Unlike traditional oil-immersed transformers, this product offers advantages such as fire and explosion resistance, low noise, low partial discharge, energy efficiency, environmental friendliness, and maintenance-free operation, making it ideal for demanding indoor power distribution environments. As a mainstream power distribution product developed in China, it features an optimized core and winding structure capable of withstanding high humidity, high altitudes, and dusty conditions. It has been successfully deployed in commercial buildings, hospitals, campuses, factories, and subway systems, providing safe and energy-efficient power solutions for diverse indoor distribution networks.

The Usune 2000kVA Three-Phase Dry Type Transformer is a core product of Zhejiang Usune Electric Co., Ltd., a specialized manufacturer dedicated to the R&D and production of power transmission and distribution equipment. The unit eliminates the need for insulating oil for cooling or insulation, instead employing an air-insulated, air-cooled design that completely removes safety risks such as oil leakage, fire, and explosion.

The transformer features a compact, lightweight design with a small footprint, facilitating easy transport and installation. As a professional transformer supplier, Usune adheres strictly to both domestic and international electrical standards throughout the entire process, exercising rigorous control over materials and craftsmanship to meet the high safety and environmental standards required for indoor power distribution applications.

2000kVA Three-Phase Dry Type Transformer2000kVA Three-Phase Dry Type Transformer2000kVA Three-Phase Dry Type Transformer

Key Performance Advantages

1. Fire and Explosion Resistance (High Safety)

The unit utilizes high-temperature-resistant insulating materials and contains no insulating oil; it eliminates risks of oil leakage, fire, and explosion, ensuring a high safety factor for use in confined spaces.

2. Green and Pollution-Free

Operation generates no oil contamination or harmful gas emissions. Indoor installation requires no oil pits or fire-isolation facilities, making it ideal for low-carbon building power distribution needs.

3. Low Noise and Low Partial Discharge

Optimized core and winding structures ensure low operating noise. Low partial discharge levels guarantee insulation stability during long-term operation and minimize the risk of failure.

4. Low Loss and Energy Efficiency

High-grade, premium silicon steel sheets are used to reduce no-load and load losses, effectively lowering electricity costs over the long term.

5. Maintenance-Free (Low O&M Costs)

The oil-free design eliminates the need for periodic oil replacement or filtration; routine maintenance requires only simple dust removal and inspection.

6. Strong Environmental Adaptability

Operates reliably in high-humidity, high-altitude, and dusty environments; suitable for specialized locations such as underground spaces, subways, hospitals, and schools.

7. Compact Structure and Easy Installation

Small footprint and lightweight design save space, while enhancing efficiency during transport and on-site hoisting/installation.

Production Quality Control and Testing Standards

1. Raw Material Inspection

Silicon steel sheets, high-temperature resistant insulation materials, and copper wires undergo rigorous sampling inspections to prevent substandard materials from entering the production line.

2. In-Process Inspection

Dedicated personnel conduct inspections during critical stages—such as core stacking, winding, and casting/curing—to correct process deviations in real-time.

3. Comprehensive Finished Product Testing

Every unit undergoes withstand voltage tests, partial discharge tests, temperature rise tests, noise tests, and loss tests; units are released for shipment only after meeting all specifications.

4. Compliance Certification

Products meet domestic power grid standards and international electrical safety codes; complete test reports are archived and available for project acceptance review.

Technical parameters

Item Technical parameter
Rated Capacity 30~2500 kVA
HV Rated Voltage 10kV / 10.5kV
LV Rated Voltage 0.4kV
Rated Frequency 50/60Hz
Vector Group Dyn11
Impedance Voltage 4%~6%(normal6%)
Item Technical parameter
Ambient Temperature -20℃~+40℃
Altitude ≤1000m
Relative Humidity ≤95%(no condensation)
Installation Site indoor

Project Reference

Cas-space Rocket Launch Project

Project ReferenceProject Reference

Cas-space Rocket Launch ProjectCas-space Rocket Launch Project

Test Report

Test ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest Report

Real-World Project Applications

Case 1: Urban Subway Station Power Distribution Project

A subway line in an East Chinese city procured 12 Usune 2000kVA Three-Phase Dry Type Transformers for indoor station power supply. Given the enclosed, humid subway environment—which demands strict fire safety and environmental compliance—the equipment has operated fault-free for three years. Stable noise and partial discharge metrics ensure the continuous, safe operation of the subway's power supply system.

Case 2: Grade-A Tertiary Hospital Power Distribution Room Upgrade

A comprehensive Grade-A tertiary hospital selected eight of these transformers to upgrade its power distribution facilities. Medical facilities require high standards for environmental cleanliness and equipment stability; the maintenance-free nature of these transformers avoids frequent inspections that could disrupt medical services. Their low-noise, pollution-free operation suits the hospital environment, while low-loss performance delivers long-term electricity cost savings.

Case 3: High-Tech Industrial Park Factory Power Supply Project

A manufacturing industrial park in Zhejiang Province installed 15 Usune 2000kVA dry-type transformers to power workshop production and office facilities. Designed to withstand heavy dust and frequent load fluctuations, this product’s robust environmental adaptability ensures stable performance under complex operating conditions, while its energy-saving features help facilities meet green production and emission reduction targets.

Installation and Usage Guidelines

1. Installation Environment Requirements

Ensure adequate ventilation and heat dissipation space around the installation site and keep the area free of flammable or explosive materials. For high-altitude or high-humidity regions, simple ventilation fans can be added to ensure effective heat dissipation; in dusty factory environments, the use of dust-proof protective mesh is recommended.

2. Foundation Installation Essentials

The unit features an integrated base for direct floor mounting, eliminating the need for a dedicated oil pit. Wiring terminals are positioned with ample clearance for easy future inspection. When installing multiple units side-by-side, maintain sufficient spacing to prevent heat accumulation.

3. Daily Operation Guidelines

The unit supports continuous 24-hour operation under normal loads; avoid prolonged operation exceeding the rated capacity. During rainy or humid seasons, regularly clean accumulated dust from the unit's surface to prevent condensation from compromising insulation performance.

FAQ

Q1: What are the key differences between the Usune 2000kVA Three-Phase Dry Type Transformer and oil-immersed transformers?

A1: The primary difference lies in the insulation and cooling medium. This dry-type transformer relies on air for insulation and heat dissipation and contains no insulating oil, thereby eliminating risks such as oil leaks, fires, and explosions at the source. It is eco-friendly, virtually maintenance-free, and ideal for enclosed indoor environments, whereas oil-immersed transformers are typically used for outdoor open-air power distribution.

Q2: What applications are suitable for the 2000kVA dry-type transformer?

A2: With strong environmental adaptability, this product is ideal for indoor power supply scenarios requiring safety, environmental compliance, and low noise levels—such as commercial complexes, schools, hospitals, factories, subways, and underground utility tunnels. It operates stably over the long term in high-humidity, high-altitude, and dusty environments, making it a preferred choice for green power grids in modern cities.

Q3: Does the Usune dry-type transformer require frequent maintenance?

A3: No; the unit features an oil-free design with air-based cooling, making it essentially maintenance-free. Unlike oil-filled transformers, there is no need for periodic replacement or testing of insulating oil; routine maintenance requires only occasional dust removal and inspection of wiring terminals. This significantly reduces the manpower and financial investment required for ongoing operations and maintenance, making it ideal for scenarios requiring long-term, continuous power supply at unmanned sites.

Hot Tags: 2000kVA Three-Phase Dry Type Transformer, China, Manufacturer, Supplier, Factory
Send Inquiry
Contact Info
If you have any inquiry about a quotation or cooperation, please feel free to email or use the following inquiry form. Our sales representative will contact you within 24 hours.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies.Privacy Policy
RejectAccept